The Journal of Thoracic and Cardiovascular Surgery
Volume 117, Issue 4 , Pages 766-775 , April 1999

Which manufacturing characteristics are predictors of outlet strut fracture in large sixty-degree Björk-Shiley convexo-concave mitral valves?

Received 24 February 1998 ,Revised 30 September 1998 ,Accepted 16 October 1998.

References 

  1. Hiratzka LF, Kouchoukos NT, Grunkemeier GL, Miller DC, Scully HE, Wechsler AS. Outlet strut fracture of the Björk-Shiley 60° convexo-concave valve: current information and recommendations for patient care. J Am Coll Cardiol. 1988;11:1130–1137
  2. Ericsson A, Lindblom D, Semb G, Huysmans HA, Thulin LI, Scully HE, et al.  Strut fracture with Björk-Shiley 70° convexo-concave valve: an international multi-institutional follow-up study. Eur J Cardiothorac Surg. 1992;6:339–346
  3. Ostermeyer J, Horstkotte D, Bennett J, Huysmans H, Lindblom D, Olin C, et al.  The Björk-Shiley 70° convexo-concave prosthesis strut fracture problem (present state of information). Thorac Cardiovasc Surgeon. 1987;35:71–77
  4. van der Graaf Y, de Waard F, van Herwerden LA, Defauw J. Risk of strut fracture of Björk-Shiley valves. Lancet. 1992;339:257–261
  5. Kallewaard M, Algra A, van der Graaf Y. Welder identity, weld date, and the risk of outlet strut fracture in Björk-Shiley convexo-concave valves: the Dutch cohort study. Heart. 1996;76:510–512
  6. Sacks SH, Harrison M, Bischler PJE, Martin JW, Watkins J, Gunning A. Metallurgical analysis of failed Björk-Shiley cardiac valve prostheses. Thorax. 1986;41:142–147
  7. Röckelein G, Breme J, von der Emde J. Lethal blockage of a Bjork-Shiley artificial heart valve caused by strut fracture—the metallurgical aspect [published erratum appears in Thorac Cardiovasc Surg 1989;37:316]. Thorac Cardiovasc Surg. 1989;37:47–51
  8. Walker AM, Funch DP, Sulsky SI, Dreyer NA. Manufacturing characteristics associated with strut fracture in Björk-Shiley 60° convexo-concave heart valves. J Heart Valve Dis. 1995;4:640–648
  9. “The FDA and Medical Device Industry” staff report for the Subcommittee on Oversight and Investigations of the Committee on Energy and Commerce, US House of Representatives. Washington [DC]: Government Printing Office; 1990;
  10. Fielder JH. Getting the bad news about your artificial heart valve. Hastings Center Rep. 1993;23:22–28
  11. Chesley SM. Worldwide call for patients with the Björk-Shiley convexo-concave heart valve [letter]. J Am Coll Cardiol. 1992;19:1368
  12. Kaplan EL, Meier P. Nonparametric estimation from incomplete observations. J Am Stat Assoc. 1958;53:457–481
  13. Cox DR. Regression models and life tables. J R Stat Soc. 1972;34:187–202
  14. Hanley JA, McNeil BJ. The meaning and use of the area under a receiver operating characteristic (ROC) curve. Radiology. 1982;143:29–36
  15. Hanley JA, McNeil BJ. A method of comparing the areas under receiving operating characteristics curves derived from the same cases [abstract]. Radiology. 1983;148:839–843
  16. Walker AM, Funch DP, Sulsky SI, Dreyer NA. Patient factors associated with strut fracture in Björk-Shiley 60 degrees convexo-concave heart valves. Circulation. 1995;92:3235–3239
  17. de Mol BA, Kallewaard M, McLellan RB, van Herwerden LA, Defauw JJ, van der Graaf Y. Single-leg strut fractures in explanted Björk-Shiley valves. Lancet. 1994;343:9–12
  18. Walker AM, Funch DP, Bianchi L, Blot WJ. Shop order fracture rate as a risk factor for strut fracture in Björk-Shiley CC 60° heart valves. J Heart Valve Dis. 1997;6:264–267
  19. Lindblom D, Björk VO, Semb BKH. Mechanical failure of the Björk-Shiley valve: incidence, clinical presentation, and management. J Thorac Cardiovasc Surg. 1986;92:894–907
  20. Piehler JM, Blackstone EH, Bailey KR, Sullivan ME, Pluth JR, Weiss NS, et al.  Reoperation on prosthetic heart valves: patient-specific estimates of in-hospital events. J Thorac Cardiovasc Surg. 1995;109:30–48
  21. Carley WM. Pfizer unit's faulty artificial heart valves are tied to falsified manufacturing records. The Wall Street Journal. 1991;
  22. Hiratzka LF, Kouchoukos NT, Grunkemeier GL, et al.  Outlet strut fracture of the Björk-Shiley 60-degrees convexo-concave valve: current information and recommendations for patient care. J Am Coll Cardiol. 1988;11:1130–1137
  23. Black RL, Strauss PJ. Important updated information for physicians about patients with Björk-Shiley 60-degree convexo-concave heart valves. Cincinnati, Ohio: Trustees for the Bowling-Pfizer Heart Valve Settlement Funds,; 1997;
  24. Grunkemeier GL, Jamieson WR, Miller DC, Starr A. Actuarial versus actual risk of porcine structural valve deterioration. J Thorac Cardiovasc Surg. 1994;98:709–718

 Members of the Netherlands Björk-Shiley Study Group are listed in the appendix.

☆☆ Address for reprints: Yolanda van der Graaf, MD, PhD, Julius Center for Patient Oriented Research, Utrecht University, Medical School, PO Box 85500, 3508 GA Utrecht, The Netherlands.

 12/1/95296

PII: S0022-5223(99)70298-9

The Journal of Thoracic and Cardiovascular Surgery
Volume 117, Issue 4 , Pages 766-775 , April 1999