The Journal of Thoracic and Cardiovascular Surgery
Volume 138, Issue 5 , Pages 1123-1128, November 2009

Effects and mechanisms of left ventricular false tendons on functional mitral regurgitation in patients with severe cardiomyopathy

Miller School of Medicine, University of Miami/Jackson Memorial Medical Center, Miami, Fla

Received 31 January 2008; received in revised form 8 August 2008; accepted 3 October 2008. published online 11 May 2009.

Objective

False tendons in the left ventricle are commonly observed. Preliminary observations associate false tendons with less functional mitral regurgitation.

Methods

Echocardiograms demonstrating severe cardiomyopathy (ejection fraction ≤30%) were retrospectively examined for left ventricular false tendons. The ejection fraction, cause of left ventricular systolic dysfunction, left ventricular diastolic dimensions, severity of mitral regurgitation, mitral annular diameter, mitral valve coaptation depth, mitral valve coaptation area, and orientation of false tendon were evaluated. The patients with false tendons were compared with a control group with cardiomyopathy without false tendons.

Results

A cohort of patients (n = 82) with severe left ventricular systolic dysfunction (mean ejection fraction, 21%) and false tendons were compared with a control group with similar left ventricular dysfunction and no false tendons (n = 121; mean ejection fraction, 20%; P = .10). The patients with false tendons had similar left ventricular diastolic internal dimensions compared with the control group (5.99 and 6.18 cm, respectively; P = .086). Yet patients with false tendons had a very low incidence of severe functional mitral regurgitation compared with the control group (4.9% vs 27%, P < .001). Patients with false tendons had significantly smaller mitral annular diameters (3.57 vs 4.03 cm, P < .001), shorter mitral valve coaptation depths (0.89 vs 1.24 cm, P < .001), and reduced coaptation areas (1.61 vs 2.52 cm2, P < .001) than the control group. The reduction of mitral regurgitation was more significant for patient with transverse midcavity false tendons.

Conclusions

Patients with false tendons and cardiomyopathy have less severe mitral regurgitation. The mechanism for the reduction in functional mitral regurgitation might be less mitral valve deformation, specifically lower coaptation depth and coaptation area when a false tendon is present.

CTSNet classification: 17, 18, 35

Abbreviations and Acronyms: CA, coaptation area, CD, coaptation depth, EF, ejection fraction, LV, left ventricular, MD, mitral annular diameter, MR, mitral regurgitation

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0022-5223(09)00424-3

doi:10.1016/j.jtcvs.2008.10.056

The Journal of Thoracic and Cardiovascular Surgery
Volume 138, Issue 5 , Pages 1123-1128, November 2009