The Journal of Thoracic and Cardiovascular Surgery
Volume 135, Issue 1 , Pages 38-43, January 2008

Diaphragmatic hernias after sequential left ventricular assist device explantation and orthotopic heart transplant: Early results of laparoscopic repair with polytetrafluoroethylene

University of Minnesota Department of Surgery, Division of Cardiovascular and Thoracic Surgery, Minneapolis, Minn.

Received 11 July 2007; received in revised form 23 August 2007; accepted 7 September 2007.

Objective

Patients who undergo an orthotopic heart transplant after explantation of an intraperitoneal left ventricular assist device are at an increased risk of developing diaphragmatic hernias. The aim of this study was to determine the incidence of these hernias and to evaluate the morbidity and short-term efficacy of laparoscopic repair.

Methods

Using our prospectively maintained database, we performed a single-institution, retrospective review of all patients who underwent laparoscopic repair of a diaphragmatic hernia resulting from defects created by left ventricular assist device explantation.

Results

From January 1, 1995 to March 1, 2007, 5 men at our institution (median age, 56 years) out of 97 patients at risk developed a diaphragmatic hernia after left ventricular assist device explantation (5.2% incidence). The median time to presentation was 25.4 months (range, 9–62 months). The median size of the hernia defect was 8 cm (range, 6–15 cm). We performed all repairs completely laparoscopically. None of the defects were repaired primarily because doing so would have resulted in significant tension. Instead, we secured a polytetrafluoroethylene patch over the defect with pledget-reinforced, braided, nonabsorbable, handsewn mattress sutures, followed by reinforcement with laparoscopic tacking screws. We noted no perioperative complications. The median length of stay was 2 days (range, 1–4 days). At a median follow-up period of 12.2 months (range, 1–31 months), no recurrences had occurred.

Conclusion

Laparoscopic repair of diaphragmatic hernias with polytetrafluoroethylene can be performed with minimal morbidity and excellent short-term results.

Abbreviations and Acronyms: LVAD, left ventricular assist device, OHT, orthotopic heart transplant, OR, operating room

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0022-5223(07)01551-6

doi:10.1016/j.jtcvs.2007.09.017

The Journal of Thoracic and Cardiovascular Surgery
Volume 135, Issue 1 , Pages 38-43, January 2008