The Journal of Thoracic and Cardiovascular Surgery
Volume 135, Issue 3 , Pages 512-520, March 2008

Solid and gaseous cerebral microembolization after biologic and mechanical aortic valve replacement: Investigation with multirange and multifrequency transcranial Doppler ultrasound

Department of Cardiothoracic Surgery, John Radcliffe Hospital, Oxford, United Kingdom

Received 17 March 2007; received in revised form 8 July 2007; accepted 10 July 2007.

Objective

Cerebral microembolization is a well-recognized phenomenon after cardiac valve replacement, but the relative proportion of solid and gaseous emboli is uncertain. Particulate microemboli are thought to be the most damaging. With the use of multifrequency transcranial Doppler ultrasound, we compared the number and nature of microemboli in recipients of biologic and mechanical aortic valve prostheses.

Methods

The middle cerebral arteries of 60 patients were monitored bilaterally with a new-generation transcranial Doppler ultrasound (Embo-Dop, DWL Elektronische Systeme GmbH, Singen, Germany) that rejects artefacts online and automatically discriminates between solid and gaseous microemboli. All recordings were performed during a 30-minute period 1 day before and at a mean of 5 days and 3 months after isolated aortic valve replacement with a biologic (30, group B) or mechanical (30, group M) prosthesis.

Results

The patients in group B were older, with a mean age of 70.6 ± 9.7 years versus 55.4 ± 9.4 years (P < .005) in the patients in group M. Biologic prosthesis recipients were all taking aspirin (no warfarin); patients with mechanical valves were well anticoagulated with warfarin both 5 days and 3 months after surgery. None of the patients had solid microemboli preoperatively. Five days postoperatively, the absolute number of cerebral microemboli was 145 and 594 for total microemboli (P = .001) and 41 and 182 for solid microemboli (P = .002) in groups B and M, respectively. At 3 months, the absolute number was 65 and 608 for total microemboli (P < .001) and 10 and 188 for solid microemboli (P < .001) in groups B and M, respectively. Solid microemboli accounted for 16% of the total microembolic load in group B compared with 31% in group M (P = .05) at 3 months.

Conclusions

Solid cerebral microemboli represent approximately one third of the total cerebral microembolic load after mechanical aortic valve replacement and are detectable in the majority of such patients both 5 days and 3 months after surgery. The neurofunctional consequences of this phenomenon should be carefully assessed.

CTSNet classification: 19, 35

Abbreviations and Acronyms: AVR, aortic valve replacement, HITS, high intensity transient signals, MCA, middle cerebral artery, TCD, transcranial Doppler

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0022-5223(07)01539-5

doi:10.1016/j.jtcvs.2007.07.062

The Journal of Thoracic and Cardiovascular Surgery
Volume 135, Issue 3 , Pages 512-520, March 2008